Oil lubrication system | Typical operating conditions | Approximate oil change interval1) |
Oil bath or oil pick-up ring | Operating temperature < 50 °C (120 °F) Little risk of contamination |
12 months
|
Operating temperature 50 to 100 °C (120 to 210 °F) Some contamination |
3 to 12 months | |
Operating temperature > 100 °C (210 °F) Contaminated environment |
3 months
|
|
Circulating oil or oil jet | All | Determined by test runs and regular inspection of the oil condition.
Dependent on how frequently the total oil quantity is circulated and whether or not the oil is cooled. |