Summary of oil change intervals for different oil systems and operating conditions

Oil lubrication system Typical operating conditions Approximate oil change interval1)
Oil bath or oil pick-up ring Operating temperature < 50 °C (120 °F) 
Little risk of contamination
12 months 

Operating temperature 50 to 100 °C (120 to 210 °F) 
Some contamination
3 to 12 months

Operating temperature > 100 °C (210 °F)
Contaminated environment
3 months 
Circulating oil or oil jet All Determined by test runs and regular inspection of the oil condition.
Dependent on how frequently the total oil quantity is circulated and
whether or not the oil is cooled.



  1. 1) More frequent oil changes are needed if the operating conditions are more demanding.

Contact us