Mounting scheme – example

Needle roller and cage assembly: K 16x22x12
Housing bore diameter: 22H6Ⓔ [mm], deviation 0/+13 μm
Shaft diameter: 16h5Ⓔ [mm], deviation 0/−8 μm
Shaft diameter Housing bore diameter
Deviation group Deviation groups
0 to +3 +3 to +6 +6 to +9 +9 to +13
Needle
roller
gauge
limits
Radial
internal
clearance
Needle
roller
gauge
limits
Radial
internal
clearance
Needle
roller
gauge
limits
Radial
internal
clearance
Needle
roller
gauge
limits
Radial
internal
clearance
µm µm









0 to −3 −5/−7 18−24 −3/-5 17−24
−3 to −6 −5/−7 18−24 −3/−5 17−25 −2/−4 18−25
−4/−6
−6 to −8 −5/−7 18−25 −3/−5 17−24 −2/−4 18−25 0/−2 17−25
−6/−8 −4/−6 −3/−5 −1/−3

The mean value of the needle roller gauge should be used to calculate the internal clearance, e.g. −6 μm for the gauge −5 to −7 μm.